CENTRIFUGE 115 V HEATED 4 PLACE FOR 12.5ML TUBES

Code: 18566

The 18500 series centrifuge has bowl heat to meet requirements for API's Manual of Petroleum Measurement Chapter 10.4. The machine is equipped with a temperature control that is set to produce an interior temperature of 140 °F, plus or minus 5°F. (60 ° C) This series does not have pre-heater pockets on the front. This makes it compact and lightweight for tight spaces.

The machine is 20 inches wide by 22 1/2 inches deep. It is 10 3/4 inches tall, and 22 inches high with the lid open. The total weight is 33 lbs. The conpactness and light weight of this unit are outstanding features for those needing to conserve space and weight.

The bowl heat for the centrifuge is controlled by a thermoswitch. It also has a manual hi/low switch. The machine is equipped with a temperature control that is set to produce an interior temperature control that is set to produce an interior temperature of 140 degrees Fahrenheit, plus or minus 5 degrees. (60 degrees Centigrade.) The temperature of the sample should not drop below 125 degrees Fahrenheit (52 degrees Centigrade)

Part # Description
18052 Motor, 115-Volt
18166 Head, 4-Place for 12.5 ML API Tube
18372 Shield for 12.5 ML API Tube with Cushion
18171 Cushion for 12.5 ML Shield

US$2,372.25

US$2,182.47

EA (1)

Features

Features

API Compliance:
Equipped with bowl heat to meet API Manual of Petroleum Measurement Standards Chapter 10.4 requirements
Temperature Regulation:
Factory-set temperature control maintains an internal temperature of 140°F ± 5° (60°C) for consistent testing conditions
Compact Design:
Does not include front-mounted pre-heater pockets, resulting in a more compact and lightweight unit ideal for tight spaces
Dimensions:
20" wide x 22 1/2" deep x 10 3/4" high (22" high with lid open)
Unit Weight:
Total weight of approximately 33 lbs
Space Efficiency:
Engineered for applications where conserving space and minimizing weight are critical
Bowl Heat Control:
Heating system is regulated by an automatic thermoswitch and supplemented with a manual high/low control switch
Sample Temperature Requirement:
Sample temperature should not fall below 125°F (52°C) to ensure accurate centrifuge results

Specifications

Specifications

Motor (Part #18052):
115 volt motor designed for consistent and reliable centrifuge operation
Head (Part #18166):
4-place centrifuge head designed for use with 12.5 ml API tubes
Shield (Part #18372):
Protective shield for 12.5 ml API tubes, supplied with integrated cushion for added stability
Cushion (Part #18171):
Replacement cushion component designed for use with 12.5 ml shield assemblies