CENTRIFUGE 115 V ELECTRIC HEAT FOR 2 PLACE PEAR SHAPE TUBES

Code: 18571

The 18500 series centrifuge has bowl heat to meet requirements for API's Manual of Petroleum Measurement Chapter 10.4. The machine is equipped with a temperature control that is set to produce an interior temperature of 140 °F, plus or minus 5°F. (60 ° C) This series does not have pre-heater pockets on the front. This makes it compact and lightweight for tight spaces.

The machine is 20 inches wide by 22 1/2 inches deep. It is 10 3/4 inches tall, and 22 inches high with the lid open. The total weight is 33 lbs. The conpactness and light weight of this unit are outstanding features for those needing to conserve space and weight.

The bowl heat for the centrifuge is controlled by a thermoswitch. It also has a manual hi/low switch. The machine is equipped with a temperature control that is set to produce an interior temperature control that is set to produce an interior temperature of 140 degrees Fahrenheit, plus or minus 5 degrees. (60 degrees Centigrade.) The temperature of the sample should not drop below 125 degrees Fahrenheit (52 degrees Centigrade)

18052 Motor, 115-Volt
18072 Head, 2-Place for Pear Shaped Tube
18080 Shield for Pear Shaped Tube

US$2,505.71

US$2,305.25

EA (1)

Features

Features

API Compliance:
Equipped with bowl heat to meet API Manual of Petroleum Measurement Standards Chapter 10.4 requirements
Temperature Regulation:
Factory-set temperature control maintains an internal temperature of 140°F ± 5° (60°C) for consistent testing conditions
Compact Design:
No front-mounted pre-heater pockets, resulting in a more compact and lightweight unit for tight space applications
Dimensions:
20" wide x 22 1/2" deep x 10 3/4" high (22" high with lid open)
Unit Weight:
Total weight of approximately 33 lbs
Space Efficiency:
Compact and lightweight construction ideal for applications where conserving space and reducing weight are critical
Bowl Heat Control:
Heating system regulated by an automatic thermoswitch with an additional manual high/low control switch
Sample Temperature Requirement:
Sample temperature should not fall below 125°F (52°C) to ensure accurate centrifuge results

Specifications

Specifications

Motor (Part #18052):
115 volt motor designed for consistent and reliable centrifuge operation
Head (Part #18072):
2-place centrifuge head designed for use with pear-shaped tubes
Shield (Part #18080):
Protective shield designed for use with pear-shaped tubes to ensure secure and stable operation