This unit has been designed in accordance with Chapter 7 Section 2 Third Edition, May 2018.
FEATURES
- User selectable auto-off timer to save battery life
- Resolution of 0.1 or .01
- Temperature range -40 to 400 degrees F
- Averaging function
- Auto-Sample function with average feature
- F to C switching
- Backlit LCD with indicating arrows indicating rate of change
- 4 Point calibration
- Cable units available
- Anodized coating for corrosion protection
- Highly durable recessed membrane switch faceplate
- Glow in the dark keypad
- Auto backlight upon power up function (Hold)
SPECIFICATIONS
Display: Amber backlit LCD with 0.45" characters with trend indication arrows and low battery and fault indication
Construction: Stainless steel temperature probe and sensor. Electronics and display in 4" x 2" x 7" anodized Aluminum enclosure. Highly durable display window, graphics and membrane switches.
Weight: Weight depends on cable length and probe style, 75' ¾ diameter probe unit 3.9 Lbs
Temperature: Resolution to 0.01 Degrees
Calibrated Accuracy: +-0.080° F from 32° to 300° F +-0.048° C from 0° to 150° C
Time Constant: 7 seconds in circulated water bath Constant: (63.2% response to temperature change)
Sensor: 100 Ohm, Class A Platinum RTD Immersion depth 4", 11cm
Battery: Energizer Ultimate Lithium L91 Intrinsically Safe Rated AA, Battery life (depending upon use) 25-150 hrs Battery Operating Range: -40°C to 60°C (-40°F to 140°F)
TYPICAL APPLICATIONS: Custody transfer, temperature baths, reference, temperature calibration for flow meters, thermowells, provers, reference, distillations, melting point tests, and flash point tests.
Industries: Laboratory, Petroleum, Pipeline, Pharmaceutical, Food & many more.
Certifications: Intrinsically safe for use in Class I, Division I Groups A, B, C, & D. Class 1, Zone 0, Group IIC Hazardous Locations CSA C/US A/Ex ia IIC T4

US$1,314.18

US$1,222.19

EA (1)

Features

Features

Auto-Off Timer:
User selectable auto-off timer to save battery life
Resolution:
Resolution of 0.1° or 0.01°
Temperature Range:
-40°F to 400°F
Averaging Function:
Built-in averaging function
Auto-Sample Function:
Auto-Sample function with averaging capability
Unit Switching:
Easy °F to °C switching
Display:
Backlit LCD with indicating arrows showing rate of temperature change
Calibration:
4-point calibration capability
Cable Options:
Cable-connected units available
Corrosion Protection:
Anodized coating for corrosion resistance
Switch Faceplate:
Highly durable recessed membrane switch faceplate
Keypad:
Glow-in-the-dark keypad
Backlight Function:
Automatic backlight upon power-up with Hold function

Specifications

Specifications

Display:
Amber backlit LCD with 0.45" characters with trend indication arrows and low battery and fault indication
Construction:
Stainless steel temperature probe and sensor. Electronics and display in 4" x 2" x 7" anodized aluminum enclosure. Highly durable display window, graphics and membrane switches
Weight:
Weight depends on cable length and probe style; 75' ¾" diameter probe unit weighs approximately 3.9 lbs
Temperature Resolution:
Resolution to 0.01°
Calibrated Accuracy:
±0.080°F from 32°F to 300°F; ±0.048°C from 0°C to 150°C
Time Constant:
7 seconds in circulated water bath (63.2% response to temperature change)
Sensor:
100 Ohm, Class A Platinum RTD; immersion depth 4" (11 cm)
Battery:
Energizer Ultimate Lithium L91 intrinsically safe rated AA. Battery life (depending upon use): 25–150 hours. Operating range: −40°C to 60°C (−40°F to 140°F)
Typical Applications:
Custody transfer, temperature baths, reference measurements, temperature calibration for flow meters, thermowells, provers, distillations, melting point tests, and flash point tests
Industries:
Laboratory, petroleum, pipeline, pharmaceutical, food, and many more
Certifications:
Intrinsically safe for use in Class I, Division I Groups A, B, C, & D. Class I, Zone 0, Group IIC Hazardous Locations. CSA C/US A/Ex ia IIC T4